Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM04107
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/14/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 01/17/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. PLUMBING INTERMEDIATE OK WITH EXCEPTION: DELETION OF P-7 WILL REQUIRE STAMPED LETTER FROM ARCHITECT/ENGINEER 2. OK TO COVER WALLS SUBJECT TO LETTER 3. FLANGES OK 4. DEMO ON EXISTING TOILET ROOM OK |
|
| 01/15/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. RE-READ PLUMBING PLAN NOTE NUMBER 6 2. VENT PIPING SHALL BE INSTALLED LEVEL OR SO DESIGNED AS TO DRAIN BACK TO THE FIXTURE SERVED 3. SEE CORRECTION NUMBER THREE FROM 12/31/07 CONTRACTOR TO PAY REINSPECTION FEE. |
|
| 01/11/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 12/31/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NOT INSTALLED PER PLAN. NO REDLINES ON SITE. 2. TRAP ARMS MAY NOT CHANGE SIZE - TRAP AND TRAP ARM TO BE THE SAME SIZE - TRAP MAY BE ONLY ONE SIZE LARGER THAN THE TAILPIECE TO WHICH IT IS CONNECTED. 3. CAP OFF ALL OPEN SEWER PIPES ASAP 4. SUPPORT ALL STUB OUTS USE APPROVED SUPPORTS SEE PLAN NOTE NUMBER 6 PLAN CALLS FOR TYPE "L" COPPER FLANGE TO BE APPROVED TYPE INSPECTION STOPPED - CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE. |
|
| 12/21/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL ALL PIPING PER APPROVED PLANS 2) PROVIDE APPROVAL SUPPORT ON ALL PIPING 3) PROVIDE TEST ON ALL PIPING |