Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM04081
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/27/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* UNABLE TO LOCATE/SIGN PERMIT CARD PLUMBING FINAL OK |
|
03/25/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. UNABLE TO LOCATE PERMIT CARD OR PREVIOUS INSPECTION HISTORY 2. HAVE ACCESS TO WATER HEATER READY AT TIME OF INSPECTION 3. CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |
|
03/24/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CONDENSATE DRAIN HOSE KINKED AND DRAIN SIZE REDUCED 2. MECHANICAL DRAIN LINE DOESN'T QUITE REACH THE MOP SINK 3. PROVIDE CLEAN BACTERIA REPORT 4. SEE DELTA ONE REVISION - MIXING VALVE AT WATER HEATER |
|
03/20/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SEE PLUMBING SPECIFICATION NOTE #22 - DISINFECTION SEE PLUMBING SPECIFICATION NOTE #24 - INSULATION 2. FLASH AND SEAL BACK SIDE OF MOP SINK 3. REQUIRE 15" FROM CENTER LINE TO SIDE WALL AT WATER CLOSET 4. PUBLIC USE LAVATORIES REQUIRE TEMPERING VALVE 5. BREAKROOM SINK REQUIRES A CLEANOUT 6. PLEASE CHECK ALL WORK, THIS MAY NOT BE A COMPLETE LIST. CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |
|
03/18/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* FLANGES OK |