Permit: T07CM04076

Parcel: 122060080

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/24/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/11/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
06/02/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NEED EXTENSION LADDER FOR ROOF AND PAST INSPECTION SHEETS
05/27/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL ALTERNATE PAHD22 HOLDOWN WHERE IT MISSED KING STUDS AT S.W. WINDOW
2) H2.5'S INSTALLED WRONG AT E. END OF TJI'S-SEE DETAIL FOR WEB STIFFNER
3) E. AND N. PORCH LEDGERS NEED POSITIVE ATTACHMENT IE...H2.5'S OR LAG BOLTS
4) NEED LADDER FOR ROOF ACCESS