Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/01/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/31/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM #2 FROM INSPECTION ON 3/26/08 NOT CORRECTED AFTER 3 ATTEMPTS |
|
| 03/28/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE LAST INSPECTION/ALSO SHIM 3 PT TRUSS REAR SLIDING DOOR 2) NOTE: MAX TRAP ARM LENGTH KIT 1 1/2" 42" YOU HAVE 58" |
|
| 03/27/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PRIOR WRITE UP FOR TRUSSES |
|
| 03/26/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHIM TRUSSES AT SGD 2) SHIM 3 PT BEARING TRUSS WEST SIDE KITCHEN 3) INSULATE BEHIND HALL TUB REMOVE BLOCK NON BEARING TRUSS MASTER BEDROOM 4) LEAK IN HOT WATER SUPPLY AT TUB 5) SINGLE WALL FURNACE VENT, HAS NEGATIVE PITCH 6) NAIL OFF FHA STRAPS DRYER DUCT AT DBL TOP PLATE 7) FLEX TO MASTER CLOSET RESTRICTED OVER 30 PERCENT 8) NO A/C SECONDARY CONDENSATE |