Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM04061

Parcel: 11207461C


Addresses:

2901 E GRANT RD


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM04061

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/07/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1. SINKS REQUIRE CLEANOUTS
2. CLEANOUTS TO OPEN IN THE DIRECTION OF FLOW
3. OK TO START BACKFILLING
4. TECHNICALLY THE SHORT SECTION OF 4" AT THE 4" X 2" REDUCER REQUIRED A FULL SIZE CLEANOUT. USING A TAPERED BUSHING IS THE PREFERRED METHOD.

REINSPECTED - 2:00 P.M
1. CORRECTION MADE OK
OK TO COVER
2. CALL 03015 FOR PRE-SLAB INSPECTION