Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T07CM04056
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2007 | ROOF NAILING | Approved | IVRS - Inspection :* | |
12/19/2007 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CORRECT NAILS IN HOLDOWNS 2) CS16 FULL LENGTH OF SHEAR PANEL NORTH SIDE 3) POST TO PLATE CONNECTION PER 221 SD 4) H3 AT 48" ON CENTER AT BACK PATIO LEDGER PER 309 SD 5) NAIL OFF HOLDOWN STUDS THROUGH OSB FULL LENGTH 6) NAIL OFF TOP OF SHEAR TO PLATES WEST SIDE 7) FRONT PORCH BEAM TO POST CONNECTION 8) STOPPED INSPECTION |