Permit: T07CM03988

Parcel: 11706183A


Addresses:

1 N 5TH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07CM03988

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/26/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
09/23/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. HAMMER ARRESTORS REQ'D AT LAUNDRY ROOM
2. SINKS REQUIRE CLEANOUTS
3. DISHWASHER MISSING SCREWS
4. ACCESS PANELS PAINTED SHUT
5. ONLY ONE SLIP NUT ALLOWED ON OUTLET SIDE OF TRAP
6. FLUSH HANDLE TO BE ON WIDE SIDE OF W.C
7. INADEQUATE NUMBER OF CLIPS ON K.S
8. CONTRACTOR TO PAY REINSPECTION FEE
09/22/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. CLOSET FLANGE OK
2. ONLY ONE SLIP NUT ALLOWED ON OUTLET SIDE OF TRAP
3. DISHWASHERS NOT SET OR HOOKED UP
4. CONTINUED "NOT READY" WILL RESULT IN
REINSPECTION FEE

THIS IS NOT A PUNCH LIST
09/17/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. WATER CLOSET SET W/O INSPECTION
2. SLIP NUT WASTE AND OVERFLOWS REQUIRE ACCESS PANEL
3. REQUIRE GRASS ADPT FITTING AT CONNECTION TO W/H SUPPORT ALL PIPING
09/10/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
09/05/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
09/04/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
09/03/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. I CALLED AND LEFT A VOICEMAIL (COURTESY CALL 1:50 PM)
WITH JEFF TO MEET ME IN THE OFFICE. NO ONE IN THE OFFICE
SEE NOTE #1 FROM 7/30/08
2. PLEASE CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL
08/19/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
FLOORS #4, #5 AND #6 STILL OK
08/13/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
FLOORS #4, #5 AND #6 PLUMBING FINAL OK
PLEASE HAVE THE WATER ON FOR INSPECTION
08/04/2008 PLUMBING - FINAL Not ready for Inspection 1. ONLY ONE SLIP NUT ON THE OUTLET SIDE OF A TRAP
2. MORE THAN 90 DEG. CHANGE OF DIRECTION ON A TRAP ARM REQUIRES AN ADDITIONAL CLEANOUT
3. SECURE DWV DRAIN HOSE WITHIN 2" OF DRAINBOARD HEIGHT
4. SINK CLIPS
5. GAS PRESSURE TEST OK - PENDING PERMIT