Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T07CM03980
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/18/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
12/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MAINTAIN 20" VERT. LAP 2. TO GET DOWN TO NATURAL SOIL FOOTINGS ARE 3' HIGH AT BACK WALL & AT SIDE 2'6 AT SIDES NO DETAIL FOR THAT HT PLEASE CHECK WITH PLAN INSPECTOR - HAVE DETAIL ON PLAN 3. UFER GRID - ALL BRASS CLAMP TIED TO 20' REBAR #4 BAR CU TO PANEL 4. 3" EARTH TO REBAR 5. MOVE FRONT PADS IN START AT 16" IN FROM END |