Permit: T07CM03970

Parcel: 133368580


Addresses:

158 N BONANZA AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/08/2008 FRAMING Approved IVRS - Inspection :*
04/04/2008 FRAMING Partial Approval IVRS - Inspection :*
1) YOU NEED ANOTHER STRINGER IN THE CENTER OF THE STAIRS
2) NEED MINIMUM 6'-8" CLEAR TO CEILING AT BATH FIXTURES
3) OK TO SHEETROCK EXCEPT STAIRS AND BATH
03/11/2008 FRAMING Partial Approval IVRS - Inspection :*
1) ADD STUDS AT MID POINT UNDER EACH LPI
02/12/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FROM LAST INSPECTION: BLOCK ALL PLYWOOD PANELS PAGE 4 SEE NOTES
2) 30' SPAN REQUIRES MID PT BEARING, GO BACK TO PLAN CHECK FOR REVISION
3) FROM LAST INSPECTION CUT INSPECTION HOLE TO VERIFY A35, AND 3 16D REQUIRED .148 DIAMETER X 3 1/2" LONG
4) CALL IN INSPECTION 01025 EXT. CLIP, NOT FRAMING
01/30/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
01/29/2008 FRAMING Not ready for Inspection IVRS - Inspection :*