Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 06/09/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. SOLAR FIN FOOTING C,D,E ON LINE 1 RFI 17 EPOXY BOLTS SPECIAL INSPECTED 2. GENERATOR & COOLING PAD TOWER |
|
| 05/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 05/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. OK TO POUR REMAINING WINDOW COLUMNS 2. OK TO POUR TRASH ENCLOSURE FOOTING PER RFI 4-08 3. PROVIDE SPECIAL INSPECTION REPORTS |
|
| 05/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR BACK WEST OPENING ON 5 WEST COLUMNS SO. WALL |
|
| 05/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* ALL POUR BACKS BUT WEST CENTER 20' WINDOW WALL COLUMNS DRY PACKED SOUTH SIDE |
|
| 04/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTING FOR STEM WALL LINE A 3 TO 4 OK TO POUR |
|
| 04/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR BACK FOOTING AT MAINTENANCE YARD SCREEN PANEL 17-S2.1 |
|
| 04/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 17 POLE BASES OK NEEDS ELEC. |
|
| 04/02/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* MAINTENANCE YARD PANELS 11, 14, 7 -- OK TO POUR |
|
| 03/27/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR PANELS 9, 13, 15, 19 TERRACON INSPECTED |
|
| 03/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR PANELS 10, 12, 16, 18 SPECIAL INSPECTOR |
|
| 02/27/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR PANELS 1, 2, 3, 4 |
|
| 02/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL PANELS 5, 6, 7, 8 NEEDS CLEARANCE TO REBAR (3) S3.1 |
|
| 01/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STAIRWELL FOOTINGS 3/E, 4/B OK TO POUR RFI FOR COMBINED POUR #4 |
|
| 01/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL ELEVATION PERIMETER FOOTINGS F/1-6, A/1-6, 1/A-F, 6/A-F COLUMN & PERIMETER FOOTINGS TERRACON SPECIAL INSP. MIKE JOHNSON |
|
| 01/09/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR COLUMN FOOTINGS B - 2, 3, 5 C - 2, 3, 4, 5 D - 2, 3, 4, 5 E - 2, 4, 5 TERRACON SPECIAL MIKE JOHNSON |