Permit: T07CM03953

Parcel: 12404102B

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T07CM03953

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/11/2008 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
02/22/2008 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
CONTR. NOT ON SITE
RECALL INSP.
01/16/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK WALL COVER
01/15/2008 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PROTECTIVE BUSHINGS FOR LOW VOLTAGE WIRING THROUGH METAL STUDS
2. PROVIDE BACK SUPPORT FOR BOXES
3. GROUND ALL METAL BOXES
4. INSTALL NAIL PLATES AS NEEDED
5. STRAP MC WITHIN 12" OF TERMINATIONS
6. IDENTIFY WHITE USED AS HOT FOR SWITCH LEGS
12/13/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK UNDERGROUND RACEWAYS
(5 THAT JUMP UNDER KITCHEN DOOR)
12/12/2007 ELECTRIC - INTERMEDIATE Cancelled IVRS - RI canceled