Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 05/02/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. HAVE APPROVED ELECTRIC PLANS ON SITE FOR ALL FUTURE INSPECTIONS 2. INSTALL RECEPTACLES IN KITCHEN AND BATHROOM AS DISCUSSED 3. OK WALLS AND HARD LIDS APARTMENT AND OFFICE |
|
| 04/23/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT USE EMT FOR SUPPORT OF LOW VOLTAGE CABLING 2. LOW VOLTAGE CABLE RUN THROUGH METAL STUDYING TO BE PROTECTED 3. MISSING SMOKE DETECTORS 4. MISSING RECEPTACLES 5. NEED REVISION FOR LIGHT FIXTURES ADDED TO APARTMENT 6. SEAL OPEN KNOCKOUTS 7. FINISH WIRING LIGHTS 8. PANELS NOT LOCATED PER PLAN 9. FAN BOXES TO BE LISTED FOR FAN USE/SUPPORT 10. SUPPORT/SECURE EMT WITHIN 3' OF BOXES |