Permit: T07CM03870

Parcel: 13329010A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/26/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
RECEIVED (1) IN HOUSE BACKFLOW CERTIFICATION
02/22/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE BACKFLOW PROTECTION WITH CERTIFICATION
FOR CUSTARD MACHINE PER NOTE #9 OF APPROVED
REVISION PLAN.
2. PROVIDE MINIMUM 1" AIR GAP FOR ALL INDIRECT DRAIN TERMINATIONS
11/09/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
COMPLY W/PREVIOUS NOTES
PERM. CAP FIXTURE OUTLETS NOT BEING USED
10/17/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. FLOOR PLAN ON APPROVED PLAN SHALL MATCH PLUMBING FIXTURES SHOWN OR PROVIDE APPROVED REVISED PLAN
2. REMOVED P-TRAP AND CAP DRAIN BESIDE EXISTING LAV IN FRONT
3. 3-COMP SINK REQUIRES WASH & RINSE TO BE DIRECTLY DRAINED THRU P-TRAP AND DRAIN LIKE ANY SINK, SANITIZE CAN BE INDIRECTLY DRAINED WITH APPROVED DRAINAGE FITTINGS & MATERIALS FOR ALL SINK DRAINAGE.