Permit: T07CM03855

Parcel: 118050010

Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Date Description Inspector Results Comments
10/27/2009 ENGINEERING - FINAL Approved All items on grading plan complete.
10/02/2009 ENGINEERING - FINAL Partial Approval OK for Temp C of O, need to complete all items on grading punch list prior to final C of O.
09/30/2009 ENGINEERING - FINAL Denied See comments under grading permit T08BU00372
09/23/2009 ENGINEERING - FINAL Denied Call for final grading permit #T08BU00372 ( expired) prior to C of O. Revise grading/site plan to reflect changes to the approved plans.
05/28/2008 ENGINEERING - FINAL Denied 1) DRAINAGE CULVERT UNDER GYMNASIUM NOT BEING INSTALLED PER APPROVED PLANS. YOU MUST HAVE APPROVED PLANS ON SITE FOR ANY WORK YOU ARE DOING.

2) INSTALLATION OF RCP PIPE UNDER A BUILDING IS A VIOLATION OF THE UNIFORM PLUMBING CODE, REFERENCE:
A) SECTION 718.3 2006 UNIFORM PLUMBING CODE "No building sewer or other drainage piping or part thereof, which is constructed of materials other than those approved for use under or within a building, shall be installed under or within 2 feet of a building...."
B) SECTION 701.1 OF THE UPC LIST MATERIALS ALLOWED UNDER A BUILDING, RCP IS NOT ONE OF THEM.