Permit: T07CM03855

Parcel: 118050010

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/13/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/05/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
01/26/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. CONCESSIONS, LOBBY #101, #102, RESTROOM 103, 104
ROUGH SOIL TEST OK (ONLY)
01/23/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. CONCESSIONS #101 IN WALL WATER TEST OK
AND VENT IN WALL TEST OK
01/22/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
2 1/2, 1 1/2, 3/4, WATER PIPING FOR RETURN DUCT TO NEW BUILDING TEST OK TO NEW WITHIN 5' ONLY
12/31/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) WEST SIDE ROUGH SOIL FOR GYM TEST OK
2) MAIN LOBBY RESTROOM PRE-SLAB OK
12/30/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) REPAIR LEAKS
2) COMPLETE PRE-SLAB
12/08/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. REDLINE ROOF DRAIN ON APPROVED PLANS
2. GRADE ON 4" FROM P-9 TO R3H OK
12/01/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
#002 MENS RESTROOM ROUGH-SOIL PROVIDE APPROVED GRADE ON 4" FROM P-9 TO P-3H OTHER ROUGH SOIL OK
11/19/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. 003 WOMENS ROUGH SOIL TEST OK
2. STUB UP IN 002 MENS RESTROOM (ONLY) TEST OK
11/18/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
PER HIGHLIGHT ON PAGE P-101
07/16/2008 PLUMBING - ROUGH, SOIL Partial Approval ALL 24" CONCRETE ENCASED SDR UNDER GYMNASIUM OK. CONCRETE COVER OK. AIR TEST AT 5 LBS OK. OK TO COVER.
07/09/2008 PLUMBING - ROUGH, SOIL Partial Approval 4 SECTIONS OF SDR DRAINAGE CULVERT GOING NORTH FROM MANHOLE OK TO COVER WITH CONCRETE. [MANHOLE NOT IN, CONNECTION FROM MANHOLE SOUTH-EAST TO EXISTING RCP NOT MADE YET.
06/23/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
HIGHLIGHT ON PAGE C-302
06/13/2008 PLUMBING - ROUGH, SOIL Partial Approval 26' OF 2" C.I.P CONNECTED TO EXISTING AND TURNED TO EAST OF WRESTLING ROOM OK TO COVER. REF. PP P-101.
05/28/2008 PLUMBING - ROUGH, SOIL Denied 1) DRAINAGE CULVERT UNDER GYMNASIUM NOT BEING INSTALLED PER APPROVED PLANS. YOU MUST HAVE APPROVED PLANS ON SITE FOR ANY WORK YOU ARE DOING.

2) INSTALLATION OF RCP PIPE UNDER A BUILDING IS A VIOLATION OF THE UNIFORM PLUMBING CODE; REFERENCE:
A) SECTION 718.3 2006 UNIFORM PLUMBING CODE "No building sewer or other drainage piping or part thereof, which is constructed of materials other than those approved for use under or within a building, shall be installed under or within 2 feet of a building...."
B) SECTION 701.1 OF THE UPC LIST MATERIALS ALLOWED UNDER A BUILDING, RCP IS NOT ONE OF THEM.
C) INSTALLATION STANDARD 1 OF THE 2006 UPC SEC. 3.6 CONCRETE SEWER PIPE; 3.6.1 MINIMUM STANDARDS; 3.6.5 "...Concrete sewer pipe shall be installed not less than 1 foot below the ground and not closer than 2 feet to a building .
05/27/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
PROVIDE APPROVED PLANS FROM CITY OF TUCSON