Inspection History Details
Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2009 | STEM WALL/RETAINING WALL | Approved | IVRS - Inspection :* | |
| 05/14/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) ALL RETAINING WALLS ON EXISTING PLAN DONE, SUBMITTING A CHANGE ORDER |
|
| 05/12/2009 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/21/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 3 WING WALLS ON PRACTICE GYM |
|
| 02/26/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* WORKING ON NE INTERIOR STEM WALL AND SO STEM WALL |
|
| 02/25/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* WORKING ON N.E. CORNER STEM WALLS |
|
| 02/18/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* EAST INTERIOR STEM WALL FROM S CORNER TO 60' NORTH |
|
| 02/13/2009 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 02/09/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* INTERIOR STEM WALL AT SE STEPS |
|
| 01/09/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* STEM WALL FOR GATOR STORAGE |
|
| 01/08/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* E LOBBY AND CONCESSION STAND 8" + 12" BLOCK STEM WITH SPECIAL INSPECTION |
|
| 12/22/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* EAST SIDE TO FINISH FLOOR |
|
| 12/19/2008 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* CALL FOR MON. |
|
| 12/17/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. RETAINING WALL TO CONTROL BY STAIRS SE CORNER 2. REQUIRES SPECIAL INSPECTION |
|
| 12/16/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* N-W-S WALLS RUN TO FINISH FLOOR N, W, S WALLS OF 107, 114, 113, 109, 126, 125, 121, 126, 106 |
|
| 12/12/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. SW FOOTINGS AT PRACTICE GYM 13' & 88'6" 2. WEST RETAINING WALL EAST SIDE OF GYM 3. SE CORNER AT STAIRS 4. TERRACON SPECIAL INSPECTED 5. CALL BACK FOR CONCESSION ROOM - 2 INTERIOR (CENTER) F5 SPREAD FOOTINGS OK TO POUR |
|
| 12/11/2008 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 12/09/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. WEST AND N.WEST PRACTICE GYM WALL - F3 & F2 FOOTING 2. STORAGE ROOM AND STAIRWELL FOOTING S-202 (3) 3. TERRACON SPECIAL INSPECTED 4. MAINTAIN REBAR CLEARANCE AND ALL CORNER BARS 5. INTERIOR CMU WALLS #5 32" O.C |
|
| 12/05/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. RETAINING WALL FOOTINGS SOUTH EASTSIDE OF NEW GYM AND 15' OF SOUTHWEST WALL 2. TERRACON SPECIAL INSPECTED |
|
| 11/05/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. ROOM 002, E, W, N WALL TO FINISH FLOOR 2. SPECIAL INSPECTED |
|
| 10/31/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. WALLS 003 TO 2' WALL 002 2'4" SHORT OF FINISH GRADE 2. TO BE SPECIAL INSPECTED |
|
| 10/27/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. 1ST LIFT W & N STEM RMS. 02, 03 2. SPECIAL INSPECTED |
|
| 10/14/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. EAST WALL WEST SIDE OF GYM OK TO CLOSE UP 2. TERRACON SPECIAL INSPECTED |
|
| 10/13/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. NORTH RETAINING WALL 0' TO 60' OFF N. CORNER OF EAST WALL |
|
| 10/10/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. EAST WALL REMAINING 20' TO NORTH CORNER OK TO CLOSE UP 2. TERRACON SPECIAL INSPECTED |
|
| 10/06/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* EAST WALL 0' TO 100' KEY WAY CHIPPED IN OR REMAINING WALL NORTH OF SOUTH END TERRACON SPECIAL INSPECTED |
|
| 10/03/2008 | STEM WALL/RETAINING WALL | Cancelled | IVRS - RI canceled | |
| 10/01/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. EAST RETAINING WALL WEST SIDE OF TRACK 57' TO 135' FROM NORTH END 2. TERRACON SPECIAL INSPECTED 3. LAST 16' OF FOOTING MISSING KEY WAY FROM S.SIDE PROVIDE ENGINEERED FIX |
|
| 09/22/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* WEST SITE WALL EAST OF BLEACHERS OK TO POUR 1. TERRACON SPECIAL INSPECTED |
|
| 09/19/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* WORKING ON WEST RAMP WALL AT BLEACHERS TO BE INSPECTED BY TERRACON |
|
| 09/16/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* START 19' SOUTH OF NE CORNER FOR 58' LOWER RETAINING WALL SK15, 25 ON S201 1. 1 1/2" WEEP HOLES 8' ON CENTER NOT INSTALLED YET 2. TO BE INSPECTED BY TERRACON |
|
| 07/11/2008 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/06/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* OK TO GROUT TO FLOOR LEVEL BOND BEAM IN PLACE SANDWICH WALLS - SPECIAL INSPECTED |