Permit: T07CM03855

Parcel: 118050010

Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Date Description Inspector Results Comments
10/09/2009 STEM WALL/RETAINING WALL Approved IVRS - Inspection :*
05/14/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) ALL RETAINING WALLS ON EXISTING PLAN DONE, SUBMITTING A CHANGE ORDER
05/12/2009 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
04/21/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
3 WING WALLS ON PRACTICE GYM
02/26/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
WORKING ON NE INTERIOR STEM WALL AND SO STEM WALL
02/25/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
WORKING ON N.E. CORNER STEM WALLS
02/18/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
EAST INTERIOR STEM WALL FROM S CORNER TO 60' NORTH
02/13/2009 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
02/09/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
INTERIOR STEM WALL AT SE STEPS
01/09/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
STEM WALL FOR GATOR STORAGE
01/08/2009 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
E LOBBY AND CONCESSION STAND 8" + 12" BLOCK STEM WITH SPECIAL INSPECTION
12/22/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
EAST SIDE TO FINISH FLOOR
12/19/2008 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
CALL FOR MON.
12/17/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. RETAINING WALL TO CONTROL BY STAIRS SE CORNER
2. REQUIRES SPECIAL INSPECTION
12/16/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
N-W-S WALLS RUN TO FINISH FLOOR
N, W, S WALLS OF 107, 114, 113, 109, 126, 125, 121, 126, 106
12/12/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. SW FOOTINGS AT PRACTICE GYM 13' & 88'6"
2. WEST RETAINING WALL EAST SIDE OF GYM
3. SE CORNER AT STAIRS
4. TERRACON SPECIAL INSPECTED
5. CALL BACK FOR CONCESSION ROOM - 2 INTERIOR (CENTER) F5 SPREAD FOOTINGS OK TO POUR
12/11/2008 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
12/09/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. WEST AND N.WEST PRACTICE GYM WALL - F3 & F2 FOOTING
2. STORAGE ROOM AND STAIRWELL FOOTING S-202 (3)
3. TERRACON SPECIAL INSPECTED
4. MAINTAIN REBAR CLEARANCE AND ALL CORNER BARS
5. INTERIOR CMU WALLS #5 32" O.C
12/05/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. RETAINING WALL FOOTINGS SOUTH EASTSIDE OF NEW GYM
AND 15' OF SOUTHWEST WALL
2. TERRACON SPECIAL INSPECTED
11/05/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. ROOM 002, E, W, N WALL TO FINISH FLOOR
2. SPECIAL INSPECTED
10/31/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. WALLS 003 TO 2'
WALL 002 2'4" SHORT OF FINISH GRADE
2. TO BE SPECIAL INSPECTED
10/27/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. 1ST LIFT W & N STEM RMS. 02, 03
2. SPECIAL INSPECTED
10/14/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. EAST WALL WEST SIDE OF GYM OK TO CLOSE UP
2. TERRACON SPECIAL INSPECTED
10/13/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. NORTH RETAINING WALL 0' TO 60' OFF N. CORNER
OF EAST WALL
10/10/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. EAST WALL REMAINING 20' TO NORTH CORNER
OK TO CLOSE UP
2. TERRACON SPECIAL INSPECTED
10/06/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
EAST WALL 0' TO 100'
KEY WAY CHIPPED IN OR REMAINING WALL
NORTH OF SOUTH END

TERRACON SPECIAL INSPECTED
10/03/2008 STEM WALL/RETAINING WALL Cancelled IVRS - RI canceled
10/01/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1. EAST RETAINING WALL WEST SIDE OF TRACK
57' TO 135' FROM NORTH END
2. TERRACON SPECIAL INSPECTED
3. LAST 16' OF FOOTING MISSING KEY WAY FROM S.SIDE PROVIDE ENGINEERED FIX
09/22/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
WEST SITE WALL EAST OF BLEACHERS OK TO POUR

1. TERRACON SPECIAL INSPECTED
09/19/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
WORKING ON WEST RAMP WALL AT BLEACHERS
TO BE INSPECTED BY TERRACON
09/16/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
START 19' SOUTH OF NE CORNER FOR 58'
LOWER RETAINING WALL SK15, 25 ON S201

1. 1 1/2" WEEP HOLES 8' ON CENTER NOT INSTALLED YET
2. TO BE INSPECTED BY TERRACON
07/11/2008 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
05/06/2008 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
OK TO GROUT TO FLOOR LEVEL BOND BEAM IN PLACE
SANDWICH WALLS - SPECIAL INSPECTED