Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/25/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
OK TO COVER WALL
10/24/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
MINIMUM DRAIN SIZE FOR A SINK IS 2"
SEE TABLE 7-5 2006
10/23/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
TRAP ARM MAY NOTE CHANGE ELEVATION POINT OF VENT MAY NOT BE BELOW TRAP WEIR
10/19/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
PROVIDE APPROVED FITTING AND SUPPORT