Permit: T07CM03843

Parcel: 125060420


Addresses:

727 N PLUMER AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/18/2008 FRAMING Approved
06/06/2008 FRAMING Partial Approval IVRS - Inspection :*
1) PENDING PLAN REVISION TO REMOVE STORAGE
2) OK TO SHEETROCK
3) JUNCTION OF SUPPLY TO PANEL UNDERGROUND 4' EAST OF STRUCTURE REQUIRED
4) U/L LISTED WATER PROOF BOX
05/28/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REVISE PLANS TO SHOW DELETION OF STORAGE/NEW EXTERIOR DOOR
2) WHATS 220 WIRE FOR AT BARAREA
3) SEAL ALL BLACK PAPER TORN/CAULK ALL PENETRATIONS