Inspection Status: Approved
Inspection History: BUILDING - PROGRESS
| Date |
Description |
Inspector |
Results |
Comments |
| 04/17/2009 |
BUILDING - PROGRESS |
|
Approved |
PER BU FINAL |
| 01/29/2009 |
BUILDING - PROGRESS |
|
Denied |
EAST SIDE H/C ACCESS RAMP APPROX. 14 FOOT IN LENGTH X 4 PLUS FOOT IN WIDTH AND HAVING A FALL OF 3/4" PER FOOT WHICH EQUALS A FALL OF 10 1/2" TOTAL MUST HAVE HANDRAILS ON BOTH SIDES THAT EXTEND 12" PAST ENDS OF RAMP AS PER 2006 IBC SECTION #1010.8 & 1012.5 |