Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM03809
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/16/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 10/13/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) SHOWER PANS AND CLOSET FLANGES OK |
|
| 10/05/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FAILURE TO READ AND FOLLOW HAND OUT INSTALLATION WITH TEST ON SHOWER LINER WILL RESULT IN REINSPECTION FEE ON FUTURE INSPECTION |
|
| 10/02/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED |
|
| 10/01/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL SHOWER LINER PER HANDOUT PER TEST |
|
| 09/28/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE SHOWER PAN HANDOUT TO CONTRACTOR |
|
| 09/09/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* WATER PROOFING ON FLOOR IS NOT A PLUMBING CODE REQUIREMENT. I DO NEED TO INSP SHOWER LINER |
|
| 07/31/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PIPE INSULATION IN WALLS OK 2) OVER HEAD AT WEST SIDE TR'S NOT COMPLETE 3) NOTE: NEED TO INSPECT SHOWER LINERS WHEN READY |
|
| 07/14/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) WATER AND WASTE WEST HALF WITH TEST OK 2) RECALL FOR INSULATION AND SPEC INFO |
|
| 07/08/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) HW PIPE INSULATION EAST SIDE 2ND LEVEL OK |
|
| 07/01/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CORRECTION AT TR 207 WITH TEST OK 2) SIZING AT MIXING VALVES TO LAVS OK PER GLHN 3) OK FOR PIPE INSULATION 2ND LEVEL |
|
| 06/24/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 412953-01 1. PIPE INSULATION THE FIRST LEVEL, EAST SIDE IS OK PROVIDED THAT ALL TUBING HAS BEEN DEBURRED PER UPC INSTALLATION STANDARD 316.1.2.3 AND CODE SECTIONS 310.3 & 609.1 2. INSTALLER WAS CAUGHT NOT FOLLOWING THESE PRESCRIBED PROCEDURES AND WAS TOLD TO CORRECT ALL AREAS THAT HAVE NOT BEEN DEBURRED. 3. PROVIDE APPROVAL FOR SIZE CHANGES AT MIXING VALVES AND LAVITORY BRANCHES 4. REDLINE ALL CHANGES |
|
| 06/18/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV WITH TEST THRU ROOF OR EXCEPT FOR AREA OF BACK PITCH 2) BELOW TR 207 AT TRIPLE WCS. SUPPORTS NOT COMPLETE. SUPPORT PIPING IN METAL STUDS. MAKE CLEANOUTS ACCESSIBLE 3) P-8 AND HW AND LAVS NOT PER PLAN. RED LINE AND REVISE FOR DELETED FIXTURES 4) OK TO INSULATE HW. PROVIDE CLEARANCE AND INSULATE THRU SUPPORTS TRISOLATORS. SPECIFIED ON CW. 100 PSI TEST ON SYSTEM |
|
| 06/16/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 06/02/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* REDLINE 3" WATER SERVICE LOCATION PROTECT PIPING PASSING THROUGH MASONRY SEE UPC 313.10 PROVIDE MATERIAL SPECS. |
|
| 02/25/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. TEST DWV PER UPC 712.2 2. INSTALL CLOSET FLANGES PER UPC IS#5 AND UPC SECTIONS 316 AND 704 3. BASIC CODE REQUIREMENTS APPLY REGARDLESS OF PLAN SPECS. |
|
| 01/30/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 01/29/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. CORRECTIONS NOT COMPLETE 2. UNABLE TO ACCESS PLANS & PERMITS |
|
| 01/28/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE 1/4" PER FOOT SLOPE 2. VENT TAKE-OFF's SHALL BE AT A TRUE 45 DEG. SO THAT THE POINT OF VENT IS ABOVE THE FLOW LINE. REF. UPC ILLUSTRATED MANUAL 3. PROVIDE A PIPING SCHEMATIC FOR COFFEE BAR |