Permit: T07CM03803

Parcel: 126041920


Addresses:

673 N CATALINA AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/15/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/05/2007 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NEED CLARIFICATION ON TRUSSES NOT BEARING PER SPECS/WITH CONNECTIONS AND CITY APPROVALS
2) NEED CROSS BRACING AT TRUSSES PER PLANS
3) NEED TO CLARIFY SHEARWALLS BEING INTERUPTED BY DOOR AND WINDOW
4) REVISE DETAIL 7-A4 WITH CITY
11/28/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL HOLDOWNS PER MANUFACTURERS SPECS
2) HOLDOWNS NEED FRAMING IN PANELS PER INSULATED PANEL MFG SPEC PB5 105
3) A4 CONNECTOR FASTENED TO TRUSS AND TOP PLATE PER 3 A4
4) DETAIL 7-A4 FOLLOWED OR HAVE PLAN REVISED
5) PEX PLUMBING PIPE OUTSIDE SOUTH 2 X 6 WALL
6) MAKE UP GROUNDS FOR EXTERIOR BOXES