Permit: T07CM03769

Parcel: 136131950


Addresses:

3121 S ALDEBARAN PL


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T07CM03769

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
04/10/2009 EXCAVATION/LAYOUT REBAR & ZON Approved
10/17/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CLOSEST POINT TO BACK SIDE OF CURB TO POST IS 14'-4"
09/26/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) VENT FOR BATHROOM PLUMBING ?
2) ARE HOLDOWNS REQUIRED ?
3) CARPORT SETBACK IS 7'-3" OTHERS WRITTEN ON PLAN
09/22/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) BLDG: ARIZONA ROOM, CEILING DRYWALL DAMAGED, PLAN CALLS FOR 2 X 8, 2 X 6 OVER HANG
2) VERIFY FTGS, NO REBAR CALLED FOR ON DETAIL 1 ?
3) HOLDOWNS REQUIRED #4 ON FOUNDATION PAGE
4) FRONT SETBACKS DON'T MATCH TO FIELD SITUATION, WHAT IS MINIMUM TO PROPERTY LINE. IS SIDE WALK PROPERTY SIDE THE PROPERTY LINE ?
5) U-VALUES CALCS VERIFY SINGLE LAYER GLASS ?
6) WERE SHEARWALLS INSTALLED
7) WERE TREATED PLATES USED ?
8) SUGGEST PERSON DOING REPAIRS MEET WITH INSPECTOR
------------------------------------------------------------------------------------------------
1) PLUMBING: ALL PLUMBING IS COVERED, LOCATE TWO WAY CLEANOUT AND UNCOVER NEW BRANCH LINE TO VERIFY MATERIAL
2) WRONG SIZE VENT MIN. 2" REQUIRED FOR BATHROOM GROUP YOU HAVE 1 1/2"
------------------------------------------------------------------------------------------------
1) ELECTRIC: SMOKE DETECTORS REQUIRED
2) LIGHT FIXTURE TO CLOSE TO SHELF IN BED CLOSET AND MUST BE CORRECT TYPE FIXTURE
3) REF. CODE REQUIRED ON PLAN SHOWS NEW 200 AMP PANEL ?
------------------------------------------------------------------------------------------------
1) MECH: MISSING EXHAUST FAN BEDROOM
2) ARIZONA HEAT SOURCE TO BE HARD WIRED, ON IT'S OWN CIRCUIT
3) WHAT TYPE DUCT WAS INSTALLED ?