Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 03/04/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO DRYWALL |
|
| 03/03/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NAIL PLATES MISSING 2. MC TO BE SECURED WITHIN 12" OF TERMINATIONS AND 6' INTERVALS 3. SEAL K.O @ INSTA-HOT BOX 4. CHECK INSTA-HOT CKT? I BELIEVE IT REQUIRES #10 NOT #12 5. LOW VOLTAGE NEEDS BUSHINGS NEED TO PAY REINSPECTION FEE IF NOT CORRECT NEXT INSPECTION |
|
| 02/29/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL MUD RINGS 2. STRAP MC WITHIN 12" OF TERMINATIONS 3. INSTALL NAIL PLATES 4. REMOVE/EXTEND WIRING IN WALL 5. INSTALL ACCESS PANEL 6. IDENTIFY WHITE USED AS HOT 7. NEED BUSHINGS FOR LOW VOLTAGE THROUGH STUDS 8. INSTA-HOTS? |
|
| 02/15/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* EXISTING ROMEX WILL STAY INSPECT FOR SAFETY |