Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* 1) OPTION A & B PORCHES |
|
| 10/17/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) THERE IS NO CITY APPROVED DESIGN FOR PORCH OPTION A, B OR C. THIS PLAN CALLS FOR PORCHES A AND B BUT UNABLE TO DETERMINE FOOTING REQUIREMENTS. HOUSE OK TO POUR. DO NOT POUR REAR PATIO SLAB |
|
| 10/16/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REBAR MUST BE 3" ABOVE SOIL 2) REBAR SPLICES MUST OVER LAP 40 ROD DIAMETER (20 INCHES) 3) YOU MUST PROVIDE AN APPROVED DETAIL FOR PORCH FOOTINGS 4) NO PORCH FOOTINGS |
|