Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T07CM03755
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
05/02/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* TIE IN FOR G.W AT WEST SIDE EXTERIOR AND NORTHSIDE EXTERIOR WITH VENT OK |
|
04/30/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* GREASE WASTE IN BAKERY/DELI AREA - OK TO COVER INTERCEPTOR SET OK TO COVER INLET, OUTLET AND VENT OK |
|
04/28/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
04/25/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - 4" SANITARY SEWER FROM PUBLIC CONNECTION BACK TO 3' INSIDE LOT WALL WATER TEST OK - 4" GW FROM CONTINUATION THRU CLEANOUT APP. 60' EAST TOWARD INTERCEPTOR LOCATION TEST OK FOR PIPING APP. 20' WEST OF INTERCEPTOR |
|
04/24/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. FIRST HUNDRED FEET OF 4" SCH 40 ABS TO CROSSING OK TO COVER. TESTED AT 5 POUNDS. 2. 3" GREASE WASTE AND VENT. FIRST 80' FROM BLDG. OK TO COVER |
|
04/18/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | - MENS RESTROOM FINAL OK - 3 FLOOR SINKS AT DELI OK - ISLAND PRODUCE HAS A WATER SUPPLY |
|
04/08/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* THREE FLOOR SINKS AT GROCERY FREEZER ADJUSTED OK OK TO COVER |
|
03/31/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
03/26/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
03/25/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
03/24/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
03/20/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
03/05/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* TWO FLOOR SINKS IN BAKERY OK TO COVER PIPE WRAPS ALONG COLUMN #3 OK |
|
03/04/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - VTR'S ALONG COLUMN #3 OK TO COVER - IT DOESN'T LOOK LIKE THE PIPE GOT WRAPPED THRU THE FLOOR - RECALL INSPECTION FOR WRAP VERIFICATION. - CLOSET FLANGES AT LADIES RESTROOM NEXT TO PHARMACY OK |
|
02/28/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* THREE FLOOR SINKS NEXT TO COLUMN #3 UNDERGROUND OK TO COVER. WATER TEST TO TEN FEET. PIPING UP TO TEN FEET |
|
02/25/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ABS DWV AT FLORAL THRU ROOF OK COLD SUPPLY OK OK TO COVER WALLS AND CEILING THIS AREA ONLY |
|
02/21/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST PAGE P1 3-FLOOR SINKS PER REDLINE P.4 INITIALED ON P.1 |
|
02/15/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* FLORAL 101 - FLOOR SINK & FLOOR SINK UNDERGROUND PER REDLINE ON SITE WATER TEST OK |
|
02/13/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* LADIES RESTROOM NEXT TO PHARMACY OK TO COVER WALLS AND OVERHEAD. NEED TO SEE FLANGES SECURED. |
|
02/08/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* DELETED CLEANOUTS CAPPED OFF OK AT BAKERY OK FLOOR SINK IN BAKERY - OK TO COVER FLOOR SINK TRAP ARM EXTENDED TO OUTSIDE WALL WILL CONTINUE AT A LATER DATE |
|
02/05/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN 2) NO RED LINES ON PLAN 3) PART OF UNDERFLOOR COVERED BY PLYWOOD |
|
02/05/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. FAMILY RESTROOM - OK TO COVER UP TO MEZZANINE FLANGE OK 2. PHARMACY OK TO COVER - REDLINE ALL CHANGES TO PLAN |
|
01/30/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
01/29/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* NEW PHARMACY SE CORNER 208-484-6520 WASTE & VENT THRU ROOF AT PHARMACY SINK OK TO COVER AFTER INSTALLING FOAM WRAPS AT CONCRETE PENETRATION DOMESTIC WATER ALSO, OK |
|
01/23/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - FAMILY RESTROOM INSTALLED PER REDLINE - ADDITIONAL FLOOR DRAIN TO BE INCORPORATED IN FUTURE PLAN REVISION. - OK TO COVER SUBJECT TO REVISED APPROVED PLAN - WATER TEST ONE RISER TO TEN FEET |
|
01/22/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. CITY CONDUCTS INSPECTIONS BETWEEN 7:00-3:30 DAILY 2. PLANS AND PERMITS ARE TO BE AVAILABLE 3. CONTINUE LEAVING MESSAGES |
|
01/18/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1. UNABLE TO LOCATE PERMIT OR APPROVED PLAN 2. ON PLUMBING PLAN - FLOOR DRAINS REDLINED ON PLAN WILL REQUIRE APPROVED REVISION 3. LEAVE A NAME AND CONTACT NUMBER WHEN SCHEDULING THIS INSPECTION. |