Permit: T07CM03753

Parcel: 114540640

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/05/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CLOSET FLANGES OK
KEEP OPEN PIPES CAPPED
04/17/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
KIT. WALL OK TO COVER
DEMO AT FS AND OLD GT OK TO COVER
04/10/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
708.0
1014.2.1
03/13/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL WALLS EXCEPT AT 3-COMP SINK
03/12/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED
03/10/2008 PLUMBING - INTERMEDIATE Cancelled
03/07/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
- DRAIN AND VENT MISSING FOR 3-COMP SINK
- 3-COMP SINK REQUIRES A DIRECT CONNECTION FOR 2 COMPS AND AN INDIRECT CONNECTION FOR SANITIZE COMP.
- NOTE: EACH FIXTURE CONNECTED TO A GFI REQUIRES
A FLOW CONTROL DEVICE CONNECTED TO A VENT SEE
UPC 1014.2.1
- PLUG ABANDON FS PRIOR TO CONCRETE
- OFFSET VENT AT MS AND PROVIDE BACKING FOR FAUCET
- HORIZONTAL ABS REQUIRES SUPPORTS AT EACH BRANCH CONNECTION AND EACH CHANGE OF ELEVATION
- TYPE M CO OK PER D.HOLLAND
- PIPING IS UNDERSIZED AT #9, 55, 56 AND 45
- INSULATE ALL PIPING PER SPEC. 1540 D PG M2
03/03/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. ADD SUPPORT FOR ALL PIPING IN WALLS
2. PLUMBING SPEC. B #2 AND REPAIR LEAKS
3. LIST NOT COMPLETE