Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CLOSET FLANGES OK KEEP OPEN PIPES CAPPED |
|
| 04/17/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* KIT. WALL OK TO COVER DEMO AT FS AND OLD GT OK TO COVER |
|
| 04/10/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 708.0 1014.2.1 |
|
| 03/13/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ALL WALLS EXCEPT AT 3-COMP SINK |
|
| 03/12/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELED |
|
| 03/10/2008 | PLUMBING - INTERMEDIATE | Cancelled | ||
| 03/07/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - DRAIN AND VENT MISSING FOR 3-COMP SINK - 3-COMP SINK REQUIRES A DIRECT CONNECTION FOR 2 COMPS AND AN INDIRECT CONNECTION FOR SANITIZE COMP. - NOTE: EACH FIXTURE CONNECTED TO A GFI REQUIRES A FLOW CONTROL DEVICE CONNECTED TO A VENT SEE UPC 1014.2.1 - PLUG ABANDON FS PRIOR TO CONCRETE - OFFSET VENT AT MS AND PROVIDE BACKING FOR FAUCET - HORIZONTAL ABS REQUIRES SUPPORTS AT EACH BRANCH CONNECTION AND EACH CHANGE OF ELEVATION - TYPE M CO OK PER D.HOLLAND - PIPING IS UNDERSIZED AT #9, 55, 56 AND 45 - INSULATE ALL PIPING PER SPEC. 1540 D PG M2 |
|
| 03/03/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. ADD SUPPORT FOR ALL PIPING IN WALLS 2. PLUMBING SPEC. B #2 AND REPAIR LEAKS 3. LIST NOT COMPLETE |