Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM03737
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/30/2007 | PLUMBING - INTERMEDIATE | Approved | ||
11/14/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK IF NO TILE |
|
10/25/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* SHALL SEE CORRECT CLOSET FLANGE INSTALL TO APPROVE INTERMEDIATE |
|
10/22/2007 | PLUMBING - INTERMEDIATE | Partial Approval | PLUMBING WEST WALL OK YOU SHALL PROVIDE CLEANOUTS ON BOTH KITCHEN SINK AND EXISTING UTILITY SINK FOR FINAL. YOU CANNOT TERMINATE CONDENSATES AT KITCHEN SINK, INSTALL PER APPROVED PLAN CONDENSATE DRAINAGE. SHALL INSPECT CORRECT CLOSET FLANGE INSTALL PRIOR TO SETTING STOOLS. |
|
10/17/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SEE NOTE #2 FROM 10/9/07 INSPECTION & COMPLY WITH CORRECT DRAINAGE FOR (2) MOP SINKS AND SEE PLAN FOR CONDENSATE TERMINATION |
|
10/09/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST DWV THRU ROOF OK WATER PIPING OK 1. SHALL SEE CORRECT CLOSET FLANGE INSTALL 2. SHALL SEE CORRECT DRAINAGE FOR WORK WITHOUT PERMIT ON WEST WALL WITH CORRECT CONDENSATE DRAIN TERMINATED PRIOR TO COVERING 3. PROVIDE HANGER SUPPORT FOR OVERHEAD VENT |