Permit: T07CM03725

Parcel: 115180050


Addresses:

1601 N ORACLE RD 05

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/23/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/17/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/17/2008 PLUMBING - INTERMEDIATE Partial Approval 1ST FLOOR CLOSET FLANGES OK. BOTH FLOORS LAUNDRY ROOM ROUGH IN OK TO COVER.
07/15/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. RE-READ NOTES FROM 02/03/08
BLDG. NUMBERS NOT POSTED
UNABLE TO LOCATE GAS PIPING
2. CLOSET FLANGES 2ND FLOOR OK
07/09/2008 PLUMBING - INTERMEDIATE Partial Approval 1. CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR
2. SECURE FLANGES TO FLOOR
04/29/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER WALLS
NEED TO SEE FLANGES
04/23/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER KITCHENETTE
02/19/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DWV W/TEST THRU ROOF OK
NEED TO SEE WATER TEST ON TUBS, WATER PIPING W/TEST THRU DIVERTER VALVES INCLUDING SHWR HEAD RISER WITH DROP EAR ELLS SECURED
02/14/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
C O SIZE PER T 7-6
SLOPE
STRAPPING
02/13/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
- POST YOUR BLDG. NUMBERS
- CONTINUED "NOT READY" WILL RESULT IN A
REINSPECTION FEE
- I DON'T HAVE TIME TO SEARCH FOR THE PLUMBER, ESPECIALLY SINCE I GAVE HIM A COURTESY CALL THAT I WAS 5 MIN. AWAY
- CONTRACTOR TO MAKE SURE WORK IS READY BEFORE CALLING INSPECTION