Permit: T07CM03719

Parcel: 141350800

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM03719

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/26/2007 FRAMING Approved IVRS - Inspection :*
12/21/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 10D NAILS AT FLOOR TRUSS SHEAR PER 303/508 DETAIL
2) DRAFT STOP 2ND FLOOR TUBS
3) FIRESTOP AROUND 3" ABS NEXT TO GARAGE SERVICE DOOR
4) BLOCK DUCT IN MASTER CLOSET AND WATER CLOSET ROOM
5) BOX NEEDED FOR 14/2 WIRE IN WATER HEATER WALL
6) PEX MIN 12" CLEARANCE TO RECESSED CAN IN FOYER