Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T07CM03716
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2007 | ROOF NAILING | Approved | IVRS - Inspection :* | |
11/20/2007 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK OSB RAN WRONG DIRECTION 2) SHEARWALL MISSING 2ND FLOOR NORTH END 3) USE CORRECT NAILS IN HOLDOWNS 4) NAIL OFF BELLY BAND NORTH END 5) NAIL OFF 303/508 DETAIL IN FLOOR TRUSSES 6) CLIP WIND BRACE AT RAT RUN |