Permit: T07CM03710

Parcel: 11621203G

Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Date Description Inspector Results Comments
11/16/2007 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
APPROVED FOR CERTIFICATE OF OCCUPANCY PENDING FIRE APPROVAL
11/15/2007 CERTIFICATE OF OCCUPANCY Denied IVRS - Inspection :
See detailed listing on site.| 999*
NO ACCESS NO ONE AT OFFICE
09/26/2007 CERTIFICATE OF OCCUPANCY Not ready for Inspection IVRS - Inspection :*
1. POST AN ADDRESS READILY VISIBLE FROM BOTH DIRECTIONS OF TRAFFIC FLOW
2. MOVABLE RAMP BY COVERED PARKING TO PROVIDE ACCESSIBLE ROUTE & FROM PORCH TO COMMON AREA
3. LANDING @ WEST GUEST ROOM MUST BE LEVEL
(LESS THAN 2% SLOPE)
4. DOOR TO ACCESSIBLE TO 32" CLEAR WIDTH WHEN OPEN
5. OR GRAB BAR 16" FROM CENTER OF TOILET ON EITHER SIDE (PICK ONE) 42" LONG 34" TO 36" ABOVE FLOOR
6. REMOVABLE SEAT & PERMANENT GRAB BARS AT TUB