Permit: T07CM03705

Parcel: 133050390


Addresses:

8801 E DEXTER DR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/24/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/21/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL GROMETT TO PROTECT WIRES BETWEEN DISCONNECT AND AC UNIT
2. RAISE OPEN TEE ON CONDENSATE DRAIN ABOVE CUTOFF SWITCH
3. SCREW WATER HEATER VENT PIPE TOGETHER
4. PVC CONDUIT MUST BE BURIED 18"
09/18/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*