10/12/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
10/11/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECTION BOTTOM PLATE EXTERIOR FOR ABS 2) INSPECTION REPORT EPOXY HOLDOWNS 3) RENAIL SHINNERS ON CSTM STRAP AT STAIRWELL 4) RENAIL OSB SHEAR ON ATTIC PANELS TO TOP PLATE |
|
10/09/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* - NAILS NEEDED IN MAS HOLD DOWNS NORTHEAST CORNER - NAIL OFF SHEAR BE FRONT DOOR PER PLAN - ADD STUD AND NAIL MAS EAST OF FRONT DOOR - RSP4 MISSING NAILS TOP PLATE SECOND FLOOR NORTHWEST CORNER - NAIL PROTECT ABS AT SILL PLATE EXTERIOR - HOLD DOWN MISSING BOLT KITCHEN WALL - TIGHTEN NUTS ON HOLD DOWN UNDER STAIRS - TIGHTEN NUTS ON ALL ANCHOR BOLTS - NAIL 2X4'S OF FLOOR TRUSS SHEAR PANELS PER PLAN - OSB FOR ATTIC SHEAR AT STAIRS BROUGHT DOWN TO TOP PLATE - SHIM 79C1B TO BEARING |