Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/28/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/20/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 1/2" FOR DEFLECTION ALL 2 POINT BEARING TRUSSES. PROVIDE COMPLETE TRUSS CALCS 2) PROVIDE SAFE ACCESS TO ROOF OSHA APPROVED EXTENSION LADDER 3) MISSING SHEAR PANEL MASTER BATH 2 X 6 WALL 4) NAIL SHEAR PANELS 6" ON CENTER TOP/TOP PLATES 5) PENDING TRUSS CALCS 6) OK TO DRY IN |
|
| 11/16/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS INSPECTION |