Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM03660

Parcel: 137050450


Addresses:

421 W IOWA ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/28/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/20/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE 1/2" FOR DEFLECTION ALL 2 POINT BEARING TRUSSES. PROVIDE COMPLETE TRUSS CALCS
2) PROVIDE SAFE ACCESS TO ROOF OSHA APPROVED EXTENSION LADDER
3) MISSING SHEAR PANEL MASTER BATH 2 X 6 WALL
4) NAIL SHEAR PANELS 6" ON CENTER TOP/TOP PLATES
5) PENDING TRUSS CALCS
6) OK TO DRY IN
11/16/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH PREVIOUS INSPECTION