Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/31/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/22/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) YOU HAVE YET TO ESTABLISH SURVEYED PROPERTY LINES ANY WHERE ON THIS PROPERTY 2) GATES LOCKED 11:15 AM |
|
| 07/11/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. COMPLETE DEMO COVERED STALLS 2. PROVIDE DDO FOR BUILDING SETBACK 3. PROVIDE SURVEYED ESTABLISHED PINS FOR ALL SETBACKS REQUIREMENTS |
|
| 01/30/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO FURTHER INSPECTIONS TO BE DONE UNTIL SITE PLAN HAS BEEN REVISED TO SHOW WHAT IS ON SITE 2) STABLE AT N.W. CORNER NOT ON SITE PLAN 3) SET BACKS NOT PER PLAN 4) REFEE WILL BE APPLIED AT NEXT INSPECTION IF ABOVE IS NOT COMPLETE PRIOR TO NEXT INSPECTION 5) LATH MUST BE INSTALLED PRIOR TO INTERMEDIATES 6) 1025 MUST BE APPROVED PRIOR |
|
| 01/16/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PORCH ENCLOSURE MUST HAVE FRAMING RAISED TO KEEP RAINWATER FROM FRAME-STUCCO MESH SHALL BE 2" MINIMUM FROM STUB 2) SMOKE ALARMS NOT WIRED 3) PROTECT ALL PLUMBING AND ELECTRIC 4) CLOSER THAN 1 1/2" FROM FACE OF STUDS 5) REVISE SITE PLAN TO SHOW ALL STRUCTURES ON PROPERTY |
|
| 12/12/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |
|
| 11/23/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* NAIL EXTERIOR OSB 6" OK ALL EDGES 12" IN FIELD WITH 8B NAIL RECALL 1025 COMPLY WITH PREVIOUS INSPECTIONS SETBACKS NOT PER PLAN REVISE PLAN TO SHOW PROPER SETBACK EAST PROPERTY LINE & ROOF ENCROACHMENT TO PROPERTY LINE. |
|
| 10/26/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES PRIOR TO FRAME INSPECTION 2) PROBLEM WITH WEEP SCREED ON SLAB ? 3) CLOSET BEND MISSING FOR WATER CLOSET N. BATH-FRAME WALLS NOT ON PLAN FOR TOILET VENT 4) NO WATER TEST ON SYSTEM AGAIN REVISE PLAN TO REFLECT AS BUILT 5) NO FTG ON FRONT PORCH |
|
| 10/25/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS 2) RECALL |
|
| 10/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REVISE DRAWING TO SHOW ALL WORK BEING DONE-SHOW PLUMBING WASTE TO REFLECT AS BUILT 2) IDENTIFY ALL ROOMS AS EXISTING OR PROPOSED, HOUSE IS GUTTED ALL NEW INTERIOR CONSTRUCTION |