Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM03624

Parcel: 103200540


Addresses:

2618 N TERESA LN

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/16/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/24/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) GARAGE HAS BEEN INSPECTED AND IS OK TO ROCK
2) STILL NEED TO INSPECT COVERED PORCH
09/19/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED 2 X 6 KING STUDS (2) ON EACH SIDE OF GLU LAM
2) 2 X 6 BOTTOM PLATE UNDER 2 X 6 KING STUDS
3) PLANS CALL FOR 4" ON CENTER NAILING ON ALL EDGES, BRACE WALL PANELS
4) MISSING H2.5 EACH STUD TOP AND BOTTOM PLATES