Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
Permit Number - T07CM03599
Inspection Description - PLUMBING - ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/02/2008 | PLUMBING - ABOVE CEILING | Approved | IVRS - Inspection :* | |
03/25/2008 | PLUMBING - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* NOT INSTALLED PER PLAN REVENT TO BE A MINIMUM OF 6" ABOVE OVER FLOOR INSTALL FULL SIZE CLEANOUT AT LAUNDRY ROOM EXPOSE CLEANOUT AT SERVICE SINK REPAIR COUPLINGS NOT PERMITTED ON NEW WORK USE SOLVENT WELD COUPLINGS |