Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T07CM03599
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/15/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
03/25/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK LAUNDRY WALL 2. HAVE OPEN CONDUCTORS (EXISTING CONDITION) @ DRYER LOCATION. NEED TO BE REPLACED WITH CABLE & JUNCTION BOXES |
|
01/25/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK WALLS & CEILINGS 2. INSTALL KNOCKOUT SEAL AT RECEPTACLE BOX BY ELECTRIC PANELS 3. INSTALL FAR SIDE SUPPORT FOR BOXES IN METAL STUDS 4. BE AWARE OF DERATING FOR CONDUCTORS TO LAUNDRY WALL 5. NEED REVISION FOR NEW WORK IN LAUNDRY WALL |