Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM03586

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/27/2008 FRAMING Approved IVRS - Inspection :*
03/26/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE BLOCK HOLDING WATER LINES AT WATER HEATER
2) INSTALL EPOXY BOLT WEST HOLDOWN AT GARAGE
3) CAULK AT T/P LINE
4) NAIL STOP #8 ROMEX ? STUD NEAR PANEL
5) NAIL STOP TOP PLATE MASTER SHOWER, TOILET AND KITCHEN SINK
6) SECURE HUNGED GAS PIPE AT FURNACE
7) PRESSURE TEST OK
8) NEED 1" CLEARANCE TO WATER HEATER B-VENT
9) EXTEND DRYER VENT THRU ROOF
10) SINGLE WALL VENT ON FURNACE RUNS DOWN HILL