Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM03586
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/27/2008 | FRAMING | Approved | IVRS - Inspection :* | |
03/26/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE BLOCK HOLDING WATER LINES AT WATER HEATER 2) INSTALL EPOXY BOLT WEST HOLDOWN AT GARAGE 3) CAULK AT T/P LINE 4) NAIL STOP #8 ROMEX ? STUD NEAR PANEL 5) NAIL STOP TOP PLATE MASTER SHOWER, TOILET AND KITCHEN SINK 6) SECURE HUNGED GAS PIPE AT FURNACE 7) PRESSURE TEST OK 8) NEED 1" CLEARANCE TO WATER HEATER B-VENT 9) EXTEND DRYER VENT THRU ROOF 10) SINGLE WALL VENT ON FURNACE RUNS DOWN HILL |