Permit: T07CM03577

Parcel: 12616319B


Addresses:

445 S ALVERNON WY

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/03/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/18/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER #118, 121, 123, 124, 126, 128 OK
08/15/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/14/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
MET WITH PHIL FOR CORRECT INSTALL OF SHOWER
WATER PROOFING
08/06/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) SHOWER UNITS #218, 222, 226 AND 228 OK
08/05/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
INSTALL LINER PER DETAIL OF HANDOUT OR YOU WILL BE REFEE'd WITH TEST IN PLACE WITH NO LEAKAGE
08/01/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS 219, 220, 221, 223, 224, 225, 227, 229, 119, 120, 121, 123, 124, 125, 127, 129 OK

SHOWERS THIS SECTION REQUIRE TEST WITH LINER
07/30/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
COMPLETE THE WATER PROOFING PER THE DETAIL,
BEFORE TILE INSTALLATION - UNIT #132 OK
07/29/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER UNIT 232 OK

1. RE-TEST UNIT #132
07/23/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS 130 THRU 136, 230 THRU 236
WATER TEST DWV & WATER PIPING OK
1. UNITS 132 & 232 REQUIRE SHOWER PAN AND TEST
07/02/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #193, 194, 195, 196, 197, 198, WATER TEST OK
07/01/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER PAN #180, 182, 292 WATER TEST OK
UNITS #293, 294, 295, 296, 297, 298 INTERMEDIATE OK
06/30/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER PAN #180 OK
06/27/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #189, 190, 191, 192, 289, 290, 291, 292 WATER TEST OK
UNITS #191 & 192 SHOWER PANS REQUIRE INSPECTION
06/19/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER PANS #181, #185, #187 OK
06/10/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER PAN #281, 285, 289 OK
06/09/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
#187, 185, 182, 181 SHOWER DRAIN TEST OK

RECEIVED OK FROM ENGINEER GIVING OK FOR ALL ITEMS DISCUSSED AT 5/27/08 INSPECTION

#281, 285, 287 PAN TEST OK
COMPLETE SUB BUILD UP CORRECTLY, OPEN UP WEEP HOLES
06/04/2008 PLUMBING - INTERMEDIATE Partial Approval UNITS #179 THRU 188 AND #279 THRU 288 OK
EXCEPT FOR UNITS 180, 181, 182, 185, 187, 281, 285, 287
NEED TO SEE CORRECT SHOWER PAN INSTALL WITH TEST AND WE NEED STAMPED SEALED LETTER FROM ENGINEER PER 5/27/08 INSPECTION
06/03/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
#181 & 182 - OK TO COVER WALLS
#179 & 180 - OK TO COVER WALLS - TUB TEST OK
#279 & 280 - OK TO COVER WALLS - TUB TEST OK
#282 - TUB OK - OK TO COVER WALLS
#281 - OK TO COVER WALLS
#183 & 184 - OK TO COVER - TUBS OK
#283 & 284 - OK TO COVER - TUBS OK
#185 & 186 - OK TO COVER - TUBS OK
#285 & 286 - OK TO COVER WALLS
#285 - SHOWER
#286 - TUB OK
05/27/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
THIS INSPECTION TO PROVIDE INFORMATION TO GENERAL AND PLUMBING CONTRACTOR. ENGINEER TO PROVIDE STAMPED LETTER TO MAKE CLEAR SCOPE OF WORK, MATERIAL TYPES, STOP USE, PIPE INSULATION, INSPECTOR NEEDS ACCESS TO ROOMS FROM INSPECTION DATED 1/09/08 PAST INSPECTIONS
12/17/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #137, 138, 139, 140, 141 OK
UNIT #270 SHOWER PAN TEST OK
12/14/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNIT 143 OK
UNITS #237, 238, 239, 240, 241, EXPOSE TUB DWV AND TEST DRAIN AND OVERFLOW.
12/13/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DRAINAGE IN CEILING UNIT 170 FOR UNIT 270 OK
12/06/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
HELD INFORMATION MEETING WITH SHORTY (LLOYD CONST.) ABOUT REQUIREMENTS FOR THIS JOB.
10/31/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #137, 138, 139, 140, 141 OK
10/26/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNIT #141 OK
AFTER HRS. INSP. CHK#4856 - $150.00
10/26/2007 PLUMBING - INTERMEDIATE Partial Approval UNIT #137, 138, 139, 140 OK
10/25/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
10/23/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #142, 145, 144, 242, 243, 244 OK
10/19/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS 245, 246 SHOWER DRAINS OK
10/18/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
10/17/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
AFTER HRS. INSP. CK#4834 -- $150.00

UNITS #145, 146 SHOWER DRAINAGE OK
10/15/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS 145, 146, 147, 245, 246, 247 OK
10/10/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #148, 149, 150, 248, 299, 250 OK
10/05/2007 PLUMBING - INTERMEDIATE Partial Approval UNITS #151 THRU 158 AND 251 THRU 258 OK
09/30/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SPECIAL REQUEST INSP. PAID BY CHECK #2182 FOR $108.00

SHOWER PAN TEST FOR UNITS #260, 262, 264, 266, 268
OK WATER TEST
09/28/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
170, 168, 164, 162, 272 -- SHOWER DRAIN, PAN WATER TEST
OK THESE UNITS
09/18/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
#172, #166, #161, #160, #268 SHOWER PAN TEST OK
09/17/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
09/10/2007 PLUMBING - INTERMEDIATE Partial Approval 1. PLAN CALLS FOR TUB AND SHOWER VALVE TO HAVE INTEGRAL STOPS
2. ROOMS #159 - #178 TUB/SHOWER CONVERSIONS MADE OK
OK TO COVER SUBJECT TO LETTER FROM ENGINEER
ROOMS #259-278 TUB/SHOWER CONVERSIONS OK
09/07/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS 159, 161, 163, 165 THRU 171 WATER TEST DRAINAGE OK
WATER PIPING OK

UNITS 259-273 ODDS ONLY WHICH HAVE TUBS DRAINAGE OK
WATER PIPING OK

UNITS #160, 162, 164 TO BE EXPOSED & TESTED

ALL SHOWER DRAINAGE TO BE TESTED
ALL SHOWER DRAINAGE TO BE INSTALLED CORRECTLY

UNIT 270 REQUIRES BUILDING INSPECTION FOR CUT PRE-STRESS CABLE.