Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/04/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & CEILINGS RMS. 121, 123, 124 |
|
| 08/01/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & CEILINGS RMS. 218-229, 118, 119, 120, 122, 125-129 |
|
| 07/22/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS AND CEILINGS RMS. 130-136, 230-236 |
|
| 06/25/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 06/23/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & CEILINGS RMS. 180, 182 |
|
| 06/10/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & CEILINGS RMS 181, 185, 187 |
|
| 06/05/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & CEILINGS RMS 281, 285, 287 |
|
| 06/02/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS & CEILINGS RMS 179, 183, 184, 186, 188, 288, 286, 284, 283, 282, 280, 279 |
|
| 12/07/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* MEETING TO DISCUSS PROJECT |
|
| 12/06/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELLED BY CONTRACTOR |
|
| 10/31/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 10/26/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS ROOM 137, 138, 139, 140, 141 ROOMS 245, 246, 145, 146 NEED MIRRORS INSTALLED TO INSPECT LIGHTS - OK GFI'S |
|
| 10/25/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK RMS 141, 140, 139 ROUGH IN WALLS |
|
| 10/23/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 10/16/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 10/15/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS RMS 247, 246, 147 |
|
| 10/10/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS RMS 150, 149, 148, 250, 249, 248 |
|
| 10/08/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS ROOMS 156, 155, 154, 153, 152, 151 |
|
| 10/05/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 09/27/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/10/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ROOMS 164, 162, 161, 259, 260, 261, 262, 263, 264, 265, 266, 267, 268, 269, 270, 271, 272, 273, 274, 275, 276, 277, 278, 168, 166 |
|
| 09/07/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. UPDATE PANEL SCHEDULE TO INDICATE NEW AC RECEPTACLE 2. INSTALL ALL SCREWS TO FASTEN RECEPTACLE TO INDUSTRIAL COVER 3. CANNOT RUN COAX CABLE WITH POWER CONDUCTORS REMOVE COAX & CLOSE UP WIRE WAY PROPERLY 4. BLANK OPEN SPACES IN PANEL DEADFRONT 5. PROPERLY ATTACH SWITCH & RECEPTACLE TO BOX IN PANEL CLOSET 6. OK WALLS RM 178, 177, 176, 175, 174, 173, 171, 170, 169, 167, 165, 163, 160 AND 159 7. REMOVE SHEETROCK ON COVERED WORK WITHOUT INSPECTIONS. CHECK BOXES SECURED & SEAL OPEN KNOCKOUTS IN BOXES. |