Permit: T07CM03570

Parcel: 140552410

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/15/2007 FRAMING Approved IVRS - Inspection :*
11/07/2007 FRAMING Partial Approval IVRS - Inspection :*
PROVIDE CITY OF TUCSON APPROVED LP1 REPAIR DESIGN FOR OVER CUT LPI IN MASTER CLOSET

OK TO INSULATE AND DRYWALL ALL BUT M/CLOSET
11/05/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPAIR I JOIST OR PROVIDE ENGINEERING FOR 2" PIPE MASTER CLOSET
2) STAPLING COMPLETE AT PIPES AND WIRES
3) ANCHOR 4 GANG BOX BOTH SIDES
4) DUCT AT N.E. BEDROOM COMPRESSED OVER 30 PERCENT