Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM03545
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/30/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/29/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK TO INSULATE 2) ADD STUDS AT SHOWER DIVERTER FOR MINIMUM 24" ON CENTER |
|
| 11/27/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ELECTRIC, GARAGE EXT. LIGHT BOX NOT INSTALLED 2) ADD 2 X 4 FLAT AT DIVERTER STUD EAST WALL TUB OVER DRILLED 3) PROTECT KIT PLUMBING AT BOTTOM PLATE 4) SHIM CRIPPLES AT FRONT DOOR HEADER 5) SHIMS AND NAILS IN LADDER BLK SHEAR TRANSFERS THRU OUT 6) DUCTS-CHECK SEAL FLEX DUCT TO UNIT LIVING ROOM SIDE IN ATTIC 7) PLASTER RING TO PENETRATE EXT. AT UFER |