Permit: T07CM03545

Parcel: 141313030

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM03545

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/23/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/19/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING NAILING AND SMALL PIECES OF OSB AT HIP TOPS
2) ATFRONT ENTRY SHIM BELOW TRUSS BEARING ABOVE WINDOW EAST WALL, TIE TO DBL T/PLATE FOR UP LIFT
3) LARGE HGU 262 HANGERS USE SINKERS IN TOE NAIL SLOTS NOT 2 1/2" 16D AT TOE NAILING ONLY
4) TIE FRONT BEDROOM SHEAR TO DRAG TRUSS