Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T07CM03500
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
02/05/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
01/31/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
10/31/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK FLOOR |
|
10/18/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* STILL NEED TO COMPLETE CORRECTIONS #1,3,9 FROM PREVIOUS INSPECTION -- OK WALL & CEILING COVER |
|
10/12/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. WIRING NOT PER PLAN 2. ROMEX TO BE PROPERLY SECURED/SUPPPORTED IN CRAWL SPACE 3. FLOOR BOXES ARE FOR RACEWAY ENTRY, NOT ROMEX 4. CEILING CANS TO BE SECURED TO STRUCTURE 5. BOXES NOT TO BE MOUNTED WITH SCREWS ON THE INTERIOR OF BOX 6. ROMEX TO BE STAPLED WITHIN 12" OF BOXES/CAN LIGHTS 7. INSTALL NAIL PLATES AS NEEDED 8. ROMEX TO BE RAN IN A NEAT AND WORKMANLIKE MANNER 9. OLD/UNUSED WIRING TO BE REMOVED WHERE ACCESSIBLE |