Permit: T07CM03500

Parcel: 12409158A


Addresses:

1809 E BROADWAY BL


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T07CM03500

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/07/2008 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
02/05/2008 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/31/2008 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
10/31/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK FLOOR
10/18/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
STILL NEED TO COMPLETE CORRECTIONS #1,3,9 FROM PREVIOUS INSPECTION -- OK WALL & CEILING COVER
10/12/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. WIRING NOT PER PLAN
2. ROMEX TO BE PROPERLY SECURED/SUPPPORTED IN CRAWL SPACE
3. FLOOR BOXES ARE FOR RACEWAY ENTRY, NOT ROMEX
4. CEILING CANS TO BE SECURED TO STRUCTURE
5. BOXES NOT TO BE MOUNTED WITH SCREWS ON THE INTERIOR OF BOX
6. ROMEX TO BE STAPLED WITHIN 12" OF BOXES/CAN LIGHTS
7. INSTALL NAIL PLATES AS NEEDED
8. ROMEX TO BE RAN IN A NEAT AND WORKMANLIKE MANNER
9. OLD/UNUSED WIRING TO BE REMOVED WHERE ACCESSIBLE