Permit: T07CM03497

Parcel: 14029212B

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
06/17/2009 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
SPOKE W/GLENN DABBS
02/05/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
28 - CMU FENCE PIERS FROM 4'8" TO 7'4" -- TOP OUT
02/04/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
28 - 2' X 2' CMU FENCE PIERS FROM 0' TO 4'8" - OK
11/05/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS AT GRID LINES C.0/4.0-5.0 @ TOP OUT (4) ARBOR COLUMNS @ TOP OUT
11/04/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ GRID LINES C.0 TO B.0/1.0 & E.0/2.0 TO 3.2 FROM 26'8" TO 29'4" AFFE -- C.0/4.0 TO 5.0 FROM 19'4"
TO 24'0" AFFE AND COURTYARD ARBOR AT COLUMN B.5
TO A.5/4.0 TO 5.0 FROM 0' TO 4'0" AFFE
11/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SPECIAL INSPECTION

NOTE: MUST HAVE APPROVED SUBMITTALS FOR WOOD TRUSSES BEFORE STARTING THEIR INSTALLATION
10/31/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. E-1 TO 4; 1-A TO E, A-1 TO 4, 4-A TO C
ALL 20 TO 25'4"
2. E-5.5 TO 6.5
7-A TO E
PARAPET WALLS TOPOUT
3. ACCEPTED SPECIAL INSPECTION
10/30/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/29/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ GRID LINES 5.0/A.0
15' NORTH OF C.O., A.0/5.0 TO 7.0, 7.0/A.0 TO F.0,
E.0/5.0 TO 7.0 FROM 20'0" TO 25'3" AFFE
ACCEPTED BY SPECIAL INSPECTOR WESTERN TECH. OK
10/27/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST 1/2 TO 20' SPECIAL INSPECTED
10/23/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
GROUTING INSPECTED AREA FROM 10/22/08
10/22/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
A-5 TO 7
E-5.2 TO 7
7-A TO E

OK TO GROUT 16 TO 20 WITH COMPLIANT SPECIAL INSPECTION
10/20/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. 4-A TO C, A-1 TO 4, 1-A TO E, E-1 TO 4 12' TO 16'
2. SPECIAL INSPECTED BY WESTERN TECH.
10/17/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. A-5 TO 7, 7-A TO E, E-5 TO 7, 5-A TO C, C-4.7 TO 5
ALL 12' TO 16' AFF

2. NEED RFI FOR COLD JOINT AT 12' INSTEAD OF 12'8"
NOTE #6 ON SCHEDULE
10/15/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
W 1/2 N, S, W WALLS INCLUDING 12" CMU OK TO GROUT
WITH SPECIAL INSPECTION
10/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ GRID LINES 5.0/7.0 - E.0/A.0-7.0
7.0/5.0 - A.0 AND A.0/C.0 - 5.0
SPECIAL INSPECTOR HAS APPROVED
10/13/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST CMU BLDG. WALL 3RD LIFT FROM 8'0" TO 12'0" @ 12'8"
ABOVE LINTELS - AFFE - OK TO GROUT
10/08/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
C-4 TO 5, E-1 TO 3.5, E-5.5 TO 7
4' TO 8' AFF
J5 JAMBS E 3.9 AND E5.1 0' TO 4'

1. WESTERN TECH. SPECIAL INSPECTED
2. NEED RFI (STAMPED) THAT THERE WILL BE SUFFICIENT CONCRETE COVERAGE WITH 6 #9 BARS IN EACH CELL AT JAMBS
10/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12" CMU OK TO GROUT TO 4'
CORRECT BARS INSTALLED
10/06/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. EXTERIOR 2ND LIFT E, N, W WALLS AND COURTYARD WALLS EXCEPT 12" CMU
2. NEEDS SPECIAL INSPECTION
10/02/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT EXTERIOR WALLS ADD 3 CORNER BARS
TO BE SPECIAL INSPECTED