Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2009 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* SPOKE W/GLENN DABBS |
|
| 02/05/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 28 - CMU FENCE PIERS FROM 4'8" TO 7'4" -- TOP OUT |
|
| 02/04/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 28 - 2' X 2' CMU FENCE PIERS FROM 0' TO 4'8" - OK |
|
| 11/05/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU WALLS AT GRID LINES C.0/4.0-5.0 @ TOP OUT (4) ARBOR COLUMNS @ TOP OUT |
|
| 11/04/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU WALLS @ GRID LINES C.0 TO B.0/1.0 & E.0/2.0 TO 3.2 FROM 26'8" TO 29'4" AFFE -- C.0/4.0 TO 5.0 FROM 19'4" TO 24'0" AFFE AND COURTYARD ARBOR AT COLUMN B.5 TO A.5/4.0 TO 5.0 FROM 0' TO 4'0" AFFE |
|
| 11/03/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SPECIAL INSPECTION NOTE: MUST HAVE APPROVED SUBMITTALS FOR WOOD TRUSSES BEFORE STARTING THEIR INSTALLATION |
|
| 10/31/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. E-1 TO 4; 1-A TO E, A-1 TO 4, 4-A TO C ALL 20 TO 25'4" 2. E-5.5 TO 6.5 7-A TO E PARAPET WALLS TOPOUT 3. ACCEPTED SPECIAL INSPECTION |
|
| 10/30/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 10/29/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU WALL REINFORCEMENT @ GRID LINES 5.0/A.0 15' NORTH OF C.O., A.0/5.0 TO 7.0, 7.0/A.0 TO F.0, E.0/5.0 TO 7.0 FROM 20'0" TO 25'3" AFFE ACCEPTED BY SPECIAL INSPECTOR WESTERN TECH. OK |
|
| 10/27/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST 1/2 TO 20' SPECIAL INSPECTED |
|
| 10/23/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GROUTING INSPECTED AREA FROM 10/22/08 |
|
| 10/22/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* A-5 TO 7 E-5.2 TO 7 7-A TO E OK TO GROUT 16 TO 20 WITH COMPLIANT SPECIAL INSPECTION |
|
| 10/20/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. 4-A TO C, A-1 TO 4, 1-A TO E, E-1 TO 4 12' TO 16' 2. SPECIAL INSPECTED BY WESTERN TECH. |
|
| 10/17/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. A-5 TO 7, 7-A TO E, E-5 TO 7, 5-A TO C, C-4.7 TO 5 ALL 12' TO 16' AFF 2. NEED RFI FOR COLD JOINT AT 12' INSTEAD OF 12'8" NOTE #6 ON SCHEDULE |
|
| 10/15/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* W 1/2 N, S, W WALLS INCLUDING 12" CMU OK TO GROUT WITH SPECIAL INSPECTION |
|
| 10/14/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CMU WALLS @ GRID LINES 5.0/7.0 - E.0/A.0-7.0 7.0/5.0 - A.0 AND A.0/C.0 - 5.0 SPECIAL INSPECTOR HAS APPROVED |
|
| 10/13/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST CMU BLDG. WALL 3RD LIFT FROM 8'0" TO 12'0" @ 12'8" ABOVE LINTELS - AFFE - OK TO GROUT |
|
| 10/08/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* C-4 TO 5, E-1 TO 3.5, E-5.5 TO 7 4' TO 8' AFF J5 JAMBS E 3.9 AND E5.1 0' TO 4' 1. WESTERN TECH. SPECIAL INSPECTED 2. NEED RFI (STAMPED) THAT THERE WILL BE SUFFICIENT CONCRETE COVERAGE WITH 6 #9 BARS IN EACH CELL AT JAMBS |
|
| 10/07/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12" CMU OK TO GROUT TO 4' CORRECT BARS INSTALLED |
|
| 10/06/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. EXTERIOR 2ND LIFT E, N, W WALLS AND COURTYARD WALLS EXCEPT 12" CMU 2. NEEDS SPECIAL INSPECTION |
|
| 10/02/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT EXTERIOR WALLS ADD 3 CORNER BARS TO BE SPECIAL INSPECTED |