Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/25/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/15/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) X-BRACE GABLE ENDS CARPORT 2) INSTALL BLOCKING RIDGE CARPORT 3) SCREWS MAY NOT BE USED ON CLIPS 4) NAIL EXTERIOR OSB STORAGE 8D 6" ON CENTER ALL EDGES 12" FIELD 5) REMOVE SCREWS FROM FHA STRAPS FROM TOP PLATES TO GABLE 6) MISSING STUDS AT PLATE JOINTS 7) EXPOSE BOTTOM PLATES VERIFY ATTACHMENT 8) PROPERTY LINE CARPORT OK 9) INSTALL RIDGE X BRACING FOR PLAN STORAGE |
|
| 07/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | IVRS - RI canceled | |
| 07/09/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* PER SET PROPERTY PINS SETBACK NOT MET 3' CARPORT OF EAST PROPERTY LINE SUBMIT AS BUILT SITE PLAN OR BUILD TO PLAN |
|
| 05/07/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) VERIFY 3' SET BACK AT CARPORT EAST PROPERTY LINE. STRING LINE TO VERIFY |
|
| 04/11/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PROPERTY PINS ON EAST SIDE TO VERIFY 3'-0" SET BACK 2) EXISTING 2 X 6 RAFTERS NEED H2.5 CONNECTION TO 2 X 12 BEAM 3) NAILING ON SHEATHING AT GARAGE NOT PER CODE 6" ON CENTER EDGES AND 12" ON CENTER FIELD 4) NEED CONNECTION ON GABLE ENDS TO TOP PLATES EXT. WALL 5) OK TO DRY IN ROOF AT STORAGE SHED |