Permit: T07CM03494

Parcel: 119222130


Addresses:

1832 W CAMELOT RD

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/25/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/15/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) X-BRACE GABLE ENDS CARPORT
2) INSTALL BLOCKING RIDGE CARPORT
3) SCREWS MAY NOT BE USED ON CLIPS
4) NAIL EXTERIOR OSB STORAGE 8D 6" ON CENTER ALL EDGES 12" FIELD
5) REMOVE SCREWS FROM FHA STRAPS FROM TOP PLATES TO GABLE
6) MISSING STUDS AT PLATE JOINTS
7) EXPOSE BOTTOM PLATES VERIFY ATTACHMENT
8) PROPERTY LINE CARPORT OK
9) INSTALL RIDGE X BRACING FOR PLAN STORAGE
07/11/2008 EXT METAL CLIPS/EXT SHEATHING Cancelled IVRS - RI canceled
07/09/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
PER SET PROPERTY PINS SETBACK NOT MET
3' CARPORT OF EAST PROPERTY LINE
SUBMIT AS BUILT SITE PLAN OR BUILD TO PLAN
05/07/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VERIFY 3' SET BACK AT CARPORT EAST PROPERTY LINE. STRING LINE TO VERIFY
04/11/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED PROPERTY PINS ON EAST SIDE TO VERIFY 3'-0" SET BACK
2) EXISTING 2 X 6 RAFTERS NEED H2.5 CONNECTION TO 2 X 12 BEAM
3) NAILING ON SHEATHING AT GARAGE NOT PER CODE 6" ON CENTER EDGES AND 12" ON CENTER FIELD
4) NEED CONNECTION ON GABLE ENDS TO TOP PLATES EXT. WALL
5) OK TO DRY IN ROOF AT STORAGE SHED