Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM03493
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED STUD AT LOW WALL BATH TUB TO SHOWER-WEST 2) REMOVE DIRT AT TUB BLOCK OUT ADD CONCRETE IF NOT THERE 3) BANG PLATE AT SHOWER DIVERTER STUD, ADD 2 X 4 FLAT 4) REMOVE OSB AT GARAGE WALL FOR DRYWALL 5) P-1 SHEAR TO BE BLOCK TRANSFER AT 16" ON CENTER 6) SHIMS AT STUDS TO HEADER, FRONT DOOR, GARAGE AT DBL 2 X 10 AND AT REAR WINDOW DINING ROOM 7) HTT IN WRONG PLACE ADD STUD NAIL TO SHEAR AND TO EXISTING STUD MOVE HTT KIT 8) BANG PLATES AT DEN, HALL ROMEX 9) ADD STUD AT (END EACH) OF TUB HALL BATH 10) HIP TRUSS CONNECTIONS AT FRONT BEDROOM 11) PLANS ARE MARKED BY COUNTY POSM0392, SEE JOB CARD NUMBER SHOULD BE T06-M0077 CIRCLED ON JOB CARD |