Inspection History Details
Inspection Status: Denied
Inspection History: ENGINEERING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/16/2009 | ENGINEERING - FINAL | Denied | -H/C PARKING SIGNS MISSING BOTH E AND W SIDE PARKING -WHEEL STOPS MISSING BOTH E AND W SIDE PARKING -CLEAN UP ALL WASHOUT AND CONSTRUCTION DEBRIS -ADDRESS LOOSE METAL IN FRONT PARKING AREA ON EAST SIDE OF PROJECT -NEED COT APPROVED STAMPED DRAWING FOR ACCESSIBLE ROUTE -ADA ROUTE NEEDS TO ADDRESS W SIDE OF ACCESSIBLE UNITS. NO ACCESSIBLE ROUTE AT S SIDE OF E H/C PARKING AREA-DOES THIS NEED TO BE SIGNED AS SUCH? -H/C ACCESSIBLE UNITS DO NOT HAVE LANDING AT ACCESS POINT ON E SIDE OF BLDG see pics 3502-3509 -COMPLETE ALL SITE WORK, ONCE SITE WORK COMPLETE REMOVE SEDIMENT CONTROLS |
|
| 03/31/2009 | ENGINEERING - FINAL | Not ready for Inspection | BUILDINGS A, B, I, J, K, L STILL IN ISSUED STATUS ADA ISSUES TO BE ADDRESSED STILL OUTSTANDING |
|
| 02/25/2009 | ENGINEERING - FINAL | Not ready for Inspection | NOT READY PLEASE COMPLETE ALL SITE WORK AND ADA ACCESSIBILITY ISSUES |