Permit: T07CM03473

Parcel: 13506136A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/05/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
11/03/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
11/02/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE MINIMUM 10 PSI TEST ON UTILITY GAS PIPING FOR FINAL
2) RECEIVED BACTERIA REPORT
10/27/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) USE PIPE CLAMPS TO SECURE ON HOSE AS HIGH AS POSSIBLE
2) TIGHTEN SOA DISPENSOR TO PROVIDE A WATER TIGHT CONNECTION
3) ALL GAS PIPING REQUIRES CLEARANCE ABOVE ROOF
4) RE-LOCATE SEDIMENT TRAPS AS NEEDED
5) CORRECT ANY DAMAGED SUPPORTS
6) PROPER SOLVENT WEIDING REQUIRES THE REMOVAL OF PAINT
7) CORRECT AT AAVS BECAUSE THOSE JOINTS CANNOT BE TESTED
8) CORRECT LEAKS
10/26/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
04/16/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ADDRESS POSTED!